Affordable and Clean Energy

Total Energy Used for all AASTMT campuses in 2021/2022

  • Total Energy Used for all AASTMT campuses in 2021/2022

1. Energy Density for AAST

The energy consumption of AAST is calculated first for each campus then the total consumption for all AASTMT campuses are computed.Table 1 shows the energy consumption during 2022 for all buildings and all branches in Alexandria.

Table 1 Analysis of Energy consumption/unit area for Alexandria branches

 

Abo kir

Maimi

Wabour

Ganekliz

Total Alex

Plan (m2)

220000

12000

6000

720

238720

Floor Area  (m2)

352000

33600

6000

720

392320

Consumption (kw)

9304497

1482312

420060

50389

11257258

Density (kw/m2)

26.43323

44.11643

70.01

70.01

28.69409

 

Similarly,  the 2022 total energy consumption in all AAST branches overall Egypt is shown in Table 2. The energy consumption of all AAST branches and the respective energy consumption percentage are shown in Figure 1 and Figure 2, respectively. It is clear that most of energy consumption in AASTMT branches occurs in Alexandria campuses since they include the highest capacity of buildings, students and staff.

Table 2 Analysis of Energy for all AAST campuses

 

Alex

Aswan

port Said

Alamin

Sheraton

Smart

Dokki

Total

Plan (m2)

3033.3

100000

100000

260000

4571.429

1750

3033.3

 

Floor Area  (m2)

14500

42000

42000

208000

32000

1750

14500

735569.7

Consumption (kw)

642621.2

1023876

939876

3949421

1411962

122540.3

642621.2

20303093

Density (kw/m2)

44.3187

24.378

22.378

18.9876

44.1238

70.023

44.3187

27.60186

 

    

Figure 1 : Energy consumption in all AASTMT campuses       Figure 2 : % Energy consumption 

 

Table3 shows the total energy in GJ and energy density in all AASTMT branches allover EGYPT. It is worth noting that more than 267 GJ were supplied from renewable energy resources which realizes AASTMT goals to divert to clean energy, reduce emissions and sustain serving the Environment.

Table 3 Energy Consumption in GJ/m2 for AAST 2021-2022

Total floor

area (m2)

Consumption from grid (kW)

Consumption from grid (GJ)

Total energy

(grid + Renewable energy resources)

Density (GJ/m2)

735569.7

20303093

73091.13

73358.25

0.09973

 

 

 

 

 

2. Renewable Energy Resources

The energy supply mainly from national grid in addition to some PV Plant in average 200kw installed on campus buildings. The national grid has 20% renewable energy according to National renewable energy Authority (NREA report 2022) as illustrated in Figure 3. Hence the total renewable energy resources in AAST consumption represents around 21.38%

Figure 3: Renewable energy in Egypt (NREA Report 2022)

                                                                                                                                                            Prepared by: Prof. Mostafa Abdel Geleil

                                                                                                                                                                                      Head of  AASTMT Energy Research Unit 

                                                                                                                                                                                      Head of AASTMT Energy Management Commitee